TC9 Thermocouples for the Steel Industry

Description

  • Temperature limits:
    -40 ... +1200 °C for type K
    0 ... +1400 °C for type S and R
    +600 ... +1600 °C for type B (see table for sheath diameters)
  • Tolerance (IEC standard 584.2/Class 1):
    For type K:
    ±2.5 °C (-40 ... +333 °C)
    ±0.0075 × [t] (t > +333 °C)
    For type S, R:
    ±1 °C (0 ... +1100 °C)
    ±[1 + 0.003 × (t - 1100)] °C (+1100 ... +1600 °C)
    For type B:
    +600 ... +1700 °C ±0.0025 × [t]
  • Ceramic insulation of the thermocouple element
  • Application versatility