AC2 Thermocouples with interchangeable insert for measure in industrial processes and furnaces

Available Configuration

Model
Element + Hot junction
Element Type
Connection Head Type
Sheath Material
Sheath Diameter (mm)
Fixed
Fixed
Fixed
Immersion Length (from 100 to 2000 mm)
Type of Transmitter
Certificates

Description

  • Amplified output signal
  • Temperature limits:
    -40 ... +350 °C for type T
    -40 ... +550 °C for type J
    -40 ... +600 °C for type E
    -40 ... +1050 °C for type K (see table for sheath diameters)
  • Tolerance:
    UNI 7938, IEC standards 584.2 / Class 1:
    for type T: ±0.5 °C (-40 ... +125 °C)
    ±0.004 [t] (t > +125 °C)
    for type J, E, K: ±1.5 °C (-40 ... +375 °C)
    ±0.004 [t] (t > +375 °C)
  • Mineral insulated interchangeable insert
  • Application versatility