TCM Mineral oxide thermocouple for use in the plastics industry

Available Configuration

Model
Element + Hot junction
Element Type
Cable (to DIN standard)
Rod Material
Rod Length
Thread
Cold Junction Type
Cable Length (from 1 to 999 dm)
Fixed
Fixed
Fixed
Fixed
Fixed
Certificates

Description

  • Max. temperature limit:
    -40 ... +400 °C
  • Reference tolerances:
    Standards IEC 584.2 Class 2:
    for type J, K:
    ±2.5 °C (-40 ... +333 °C)
    ±0.0075 [t] (t > +333 °C)
  • Thermoelement with compact isolation and continuous metal sheathing (MgO insulation)
  • Cable compliant with DIN standards