Temperature limits:
- 40 ... + 310 ° C for type T
- 40 ... + 550 ° C for type J
- 40 ... + 600 ° C for type E
- 40 ... + 1050 ° C for type K
(see table for sheath diameters)
Tolerance (IEC standard 584.2/Class 1):
for type T:
± 0,5 ° C (- 40 ... + 125 ° C)
± 0.004 [t] (t > + 125 ° C)
for type J, E, K:
± 1.5 ° C (- 40 ... + 375 ° C)
± 0.004 [t] (t > + 375 ° C)
Mineral insulated (MgO) thermocouple element and continuous metal sheath